| Error Codes |
| Code |
Description |
| 001 |
Internal Error: System had to reload default settings |
| 050 |
Shorted Temperature Probe |
| 051 |
Open Temperature Probe |
| 075 |
Brew basket lock or sensor failure |
| 100 |
Initial Fill Error: Initial fill time was more than 15 minutes |
| 101 |
Error on Refill: Tank did not refill with in 3 minutes |
| 102 |
Unwanted Fill: When brewer is idle, the fill valve was activated for more than 30 seconds during a 1 hour period |
| 200 |
Flat Line Temperature: (Water is Boiling) System is calling for heat, but the temperature does not rise at least 2°F within 10 minutes |
| 201 |
Heater Open: System is calling for heat but the temperature does not rise at least 2°F within 10 minutes |
| 202 |
Relay/Triac Stuck Closed: System is not calling for heat, but temperature rises more than 5 degrees |
| 255 |
Key Pad Error: A switch was pressed for more than 45 seconds |